Choosing the right X-ray test pieces is an important part of maintaining a reliable foreign material inspection program in food manufacturing. While metal detectors identify metallic contaminants, X-ray systems can detect certain nonmetallic materials, including glass, ceramic, stone, and calcified bone.
However, not every X-ray system can detect every contaminant. Detection performance depends on material composition, contaminant size, product density, packaging, and equipment settings.
For QA managers, food safety teams, and engineering leads, selecting the correct test pieces starts with understanding which foreign materials could enter their products.
This guide explains the differences between common X-ray test materials, how to choose test card formats, and how to verify inspection performance under actual production conditions.
How X-Ray Inspection Finds Contaminants
X-ray inspection works by measuring how much X-ray energy passes through a product. Materials that absorb more energy than the surrounding food can appear as contrasting areas in the inspection image.
Unlike conventional metal detection, which responds to electromagnetic properties, X-ray inspection relies primarily on differences in X-ray attenuation, influenced by density, composition, and thickness.
This allows X-ray systems to identify certain contaminants that conventional metal detectors cannot detect.
Depending on the application, X-ray inspection may identify glass, ceramic, stone, calcified bone, ferrous metal, non-ferrous metal, stainless steel, and some dense plastics or rubber compounds.
X-ray systems can also inspect products packaged in aluminum foil or metallized materials, although packaging characteristics can influence performance.
However, low-density plastics, wood, hair, and other materials with properties similar to the surrounding food may be difficult to detect reliably.
For a closer comparison of inspection technologies, read Metal Detectable vs X-Ray Visible Materials: What's the Difference?
Why X-Ray Inspection Needs Different Test Pieces
Traditional metal detector testing commonly uses three reference materials: ferrous metal (Fe), non-ferrous metal (NFe), and stainless steel 316 (SS 316).
These materials help verify metal detection performance, but they do not represent every foreign material an X-ray inspection system may need to identify.
For example, a facility using glass containers may face glass contamination risks. Another facility may use ceramic processing components or aluminum packaging materials.
Testing only stainless steel would not demonstrate the system's ability to detect those additional hazards.
X-ray inspection test cards provide controlled reference materials in known sizes, allowing facilities to challenge their equipment using contaminants relevant to their production environment.
Common X-ray test materials include soda-lime glass, ceramic, aluminum, ferrous metal, non-ferrous metal, and stainless steel 316.
The correct combination should be established through the facility's hazard analysis, equipment capabilities, and applicable customer requirements.
Match X-Ray Test Materials to Your Hazard Analysis
Not every food manufacturer needs the same X-ray test materials. The most useful approach is to evaluate the potential sources of foreign material contamination throughout the production process.
Soda-Lime Glass Test Pieces
Glass contamination can originate from jars, bottles, containers, lighting, or certain processing components.
A soda lime glass test piece allows facilities to evaluate whether their X-ray system can identify representative glass fragments under defined operating conditions.
Blue Supply Company offers the X-Ray Soda Lime Glass Test Card in multiple contaminant sizes.
Facilities can also consider Thermoform Soda-Lime Glass Test Cards when a different card construction is preferred.
Glass composition matters because different types of glass can produce different X-ray responses. Facilities inspecting glass containers should consult their equipment manufacturer about selecting representative reference materials.
Ceramic X-Ray Test Pieces
Ceramic contamination may originate from machine components, fittings, processing equipment, or other materials used throughout a facility.
Because ceramic is nonmetallic, conventional metal detectors generally cannot identify it.
A ceramic X-ray test piece provides a way to evaluate the system's ability to detect this type of dense, nonmetallic material.
Blue Supply Company's Thermoform Ceramic Test Cards offer a practical option for facilities including ceramic hazards in their inspection programs.
Testing should use the approved contaminant diameter and representative product conditions.
Aluminum X-Ray Test Pieces
Aluminum may be present in processing equipment, packaging components, foil materials, and other manufacturing supplies.
Although aluminum is metallic, its X-ray response differs from that of denser metals such as stainless steel.
This makes aluminum an important reference material when the facility's hazard analysis identifies it as a potential contaminant.
Blue Supply Company offers Thermoform Aluminum Test Cards for X-ray inspection testing.
Facilities using foil packaging should also confirm how packaging affects detection performance. An X-ray system capable of inspecting foil-packed products is not automatically capable of detecting every aluminum fragment within that packaging.
Ferrous, Non-Ferrous, and Stainless Steel 316 Test Pieces
Metal contaminants remain relevant even when a facility uses X-ray inspection instead of conventional metal detection.
Ferrous metal may originate from carbon steel components, fasteners, or tools. Non-ferrous contamination may involve brass, copper, or aluminum components. Stainless steel contamination may come from processing machinery, cutting equipment, or other stainless components.
Blue Supply Company's Laminated X-Ray Test Cards for Fe, NFe, and SS 316 provide reference standards for evaluating detection of these materials.
For additional guidance on metal reference diameters, read Metal Detector Test Piece Sizes: Fe, NFe & Stainless Guide.
X-Ray Test Card Formats: Acetal, Thermoform, and Laminated
After selecting the appropriate contaminant material, the next decision is choosing a test card format.
Card construction affects handling, durability, and suitability for different production environments.
Acetal X-Ray Test Cards
Acetal test cards use a rigid plastic housing designed to securely contain a known reference contaminant.
Their solid construction makes them convenient for routine handling and inspection checks.
Blue Supply Company's X-Ray Soda Lime Glass Test Card is an example of this format.
Acetal cards can be suitable for facilities seeking a durable, easy-to-handle test standard for their approved inspection procedure.
Thermoform X-Ray Test Cards
Thermoform cards use formed plastic construction to contain the reference material.
Blue Supply Company's thermoform options use PETG construction and are designed for demanding production environments, including applications where moisture and frequent handling are considerations.
Available materials include soda-lime glass, ceramic, and aluminum.
These cards may be useful for facilities that regularly handle test standards near wet processing areas or exposed production environments.
Laminated X-Ray Test Cards
Laminated test cards offer a thinner, more flexible alternative to rigid formats.
They are convenient for storage, handling, and certain packaged-product inspection procedures.
Blue Supply Company's Laminated X-Ray Test Cards are available with ferrous, non-ferrous, and stainless steel 316 reference materials.
Regardless of card construction, facilities should confirm that the format is compatible with their inspection equipment and approved testing method.
When to Consider an X-Ray Test Puck
Some applications benefit from a smaller, puck-shaped test standard rather than a flat card.
Blue Supply Company offers the X-Ray Soda-Lime Glass Test Puck as an additional format option.
Before selecting a puck, confirm that its dimensions and handling requirements are suitable for the inspection system and that it can be safely recovered after testing.
Where to Place X-Ray Test Pieces During Verification
Choosing the correct test material is only part of a reliable X-ray verification program.
Test piece placement can significantly influence detection performance because X-ray sensitivity varies with product thickness, density, packaging, and inspection geometry.
For conveyor systems, facilities should evaluate test positions across the belt width and within the product or package.
Testing should include the system's established least-sensitive location and other challenging positions identified during validation.
For example, a contaminant positioned within the densest portion of a product may be more difficult to distinguish from the surrounding food.
When practical, test pieces should be placed inside a clearly identified representative product pack. If that is not possible, use the alternative method approved by the equipment manufacturer and the facility's documented procedure.
Testing should also occur at normal production speed using the correct product program and inspection settings.
Most importantly, confirm that the system not only identifies the test piece but also rejects or otherwise controls the affected product correctly.
Record the material, diameter, placement, result, time, and operator responsible for the check.
What Auditors Expect: BRCGS Issue 9 Clause 4.10.3.5
Facilities certified to BRCGS Global Standard Food Safety Issue 9 should review section 4.10.3, which addresses metal detection and X-ray equipment.
Clause 4.10.3.5 establishes requirements for testing procedures, including the use of appropriate reference materials and confirmation of inspection and rejection performance.
For X-ray systems, facilities should have documented procedures that identify the required test materials, contaminant sizes, testing positions, frequency, responsibilities, and acceptance criteria.
Auditors may review whether testing is performed under normal operating conditions, whether the appropriate challenge standards are used, and whether the reject mechanism functions correctly.
They may also examine completed records and investigate how the facility responds when a test fails.
If an X-ray system fails a required check, potentially affected product must be controlled according to the site's documented failure procedure.
For additional guidance on testing schedules, recordkeeping, and corrective actions, read Metal Detector Verification: How Often to Test + Free Log.
Always consult the current applicable BRCGS standard, equipment manufacturer's instructions, and customer specifications when establishing or updating an X-ray inspection procedure.
Frequently Asked Questions About X-Ray Test Pieces
Can You Use Metal Detector Test Pieces on an X-Ray Machine?
Yes, some metal detector test pieces can also be used for X-ray inspection, provided their construction and contaminant characteristics are suitable for the equipment and testing procedure.
However, metal test pieces alone do not demonstrate the system's ability to detect nonmetallic contaminants such as glass or ceramic.
What Contaminants Can X-Ray Inspection Detect?
Depending on the equipment and product, X-ray inspection may detect metal, glass, ceramic, stone, calcified bone, and certain dense plastics or rubber materials.
Detection performance depends on contaminant size, composition, product characteristics, packaging, and inspection settings.
Can X-Ray Detect Plastic?
Some plastics can be detected by X-ray inspection, particularly when they contain dense additives or provide sufficient contrast against the surrounding product.
However, many conventional low-density plastics are difficult to detect reliably.
Facilities should verify plastic detectability using representative materials and actual production conditions rather than assuming all plastics are X-ray visible.
How Often Should X-Ray Systems Be Tested?
X-ray testing frequency should be established through the facility's risk assessment, applicable certification standards, customer requirements, and equipment instructions.
Checks commonly occur at start-up, at documented intervals during production, after relevant equipment changes or maintenance, and at the end of production.
The exact frequency should account for how much potentially affected product the facility can identify and control if a test fails.
Choose the Right X-Ray Test Pieces for Your Facility
A reliable X-ray inspection program begins with selecting test materials that reflect the foreign material hazards present in the production environment.
Soda-lime glass, ceramic, aluminum, ferrous metal, non-ferrous metal, and stainless steel 316 each provide a different inspection challenge.
By selecting appropriate contaminant sizes, card formats, and testing positions, food manufacturers can better evaluate the performance of their inspection equipment.
Blue Supply Company supplies X-ray test pieces in multiple materials and formats to support food manufacturing inspection programs.
Explore our Soda Lime Glass Test Cards, Ceramic Thermoform Cards, Aluminum Thermoform Cards, and Fe, NFe, and SS 316 Laminated Test Cards.
Need assistance selecting the right X-ray test materials, contaminant diameters, or card formats?
Contact Blue Supply Company at service@bluesupplycompany.com or call (888) 585-8725.